VAT

Weidmuller Photovoltaics Combiner Box Fireman's switch PV Next DC Combiner Box 2 In / 2 Out 10 MPP RD WM4 11

Product Code: 8000130052

Price
£3096.23 ex. VAT £3715.48 inc. VAT

Call For Availability


Add To Favourites

Product Overview

Weidmuller PVC DC Combiner Box 2 In / 2 Out 10 MPP RD WM4 11 (8000130052) Combiner Box (Photovoltaik) PV Next 10 MPP's 2 Inputs / 2 Outputs per MPP Remote disconnector WM4C 1100 VCombiner box for inverters with Fireman switch for the connection to 10 MPP tracker. Suitable for remote disconnection of the DC side by the fire department according to VDE-AR-E2100-712. Max. string voltage Uoc: 1100 VDC MPP1: 2 inputs connection via WM4 C connector compatible with cable type T-V 2 Pfg1169/08.07 / EN 50618:2063 2 outputs connection via WM4 C connector compatible with cable type T-V 2 Pfg1169/08.07 / EN 50618:2063 MPP2 to 10: identical to MPP1 DC fireman switch: Switching off by undervoltage triping. Switching off by reaching a temperature of >= 100 -C in the housing. Automatic reconnection after the control voltage (230 V AC) is applied again. With signal contact. Connection of the fireman switch control line 230 VAC via M16 cable glands (Clamping range 5-10 mm2) max. conductor cross-section: 1.5 mm2. Connection of the signal contact 24 VDC (max. 300 mA) via M16 cable glands (Clamping range 5-10 mm2) max. conductor cross-section: 1.5 mm2. Protection class: IP65. All built into a glas fibre reinforced polyester housing. Dimensions HxWxD: 485x600x250 mm. Approval according to low voltage switchgear IEC 61439-1 and EN 61439-2

Key Features

  • Combiner Box (Photovoltaik) PV Next 10 MPP's 2 Inputs / 2 Outputs per MPP Remote disconnector WM4C 1100 VCombiner box for inverters with Fireman switch for the connection to 10 MPP tracker.
  • Suitable for remote disconnection of the DC side by the fire department according to VDE-AR-E2100-712.
  • Max. string voltage Uoc: 1100 VDC MPP1: 2 inputs connection via WM4 C connector compatible with cable type T-V 2 Pfg1169/08.07 / EN 50618:2063 2 outputs connection via WM4 C connector compatible with cable type T-V 2 Pfg1169/08.07 / EN 50618:2063 MPP2 to 10: identical to MPP1 DC fireman switch: Switching off by undervoltage triping.
  • Switching off by reaching a temperature of >= 100 -C in the housing.
  • Automatic reconnection after the control voltage (230 V AC) is applied again.
  • With signal contact.
  • Connection of the fireman switch control line 230 VAC via M16 cable glands (Clamping range 5-10 mm2) max. conductor cross-section: 1.5 mm2.
  • Connection of the signal contact 24 VDC (max.
  • 300 mA) via M16 cable glands (Clamping range 5-10 mm2) max. conductor cross-section: 1.5 mm2.
  • Protection class: IP65.
  • All built into a glas fibre reinforced polyester housing.
  • Dimensions HxWxD: 485x600x250 mm.
  • Approval according to low voltage switchgear IEC 61439-1 and EN 61439-2

Specifications

  • SKU: 8000130052
  • Heading: Weidmuller PVC DC Combiner Box 2 In / 2 Out 10 MPP RD WM4 11
AC/DC AC / DC
Application Low Voltage
Voltage 1100V / 230V AC / 24V
IP Rating IP65
Product Type PVC
UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE